Skip to main content
Ecolink, Inc.
Q
  1. Home
  2. Electrical Contact Cleaning Solutions
  3. Cleaning Electrical Components with POSITRON: What to Check Before You Start

Cleaning Electrical Components with POSITRON: What to Check Before You Start

Ecolink Green Icon
Ecolink Blue And Green Icon

Last updated:

Electrical equipment collects oil mist, dust, and carbon over time, and that buildup makes inspection and maintenance harder. Here at Ecolink, we offer industrial degreasers and solvents for a wide array of cleaning needs, including those for electrical equipment cleaning. In this post, we will focus on our product POSITRON, a dielectric solvent, and what to check before cleaning electrical components with it.

Before cleaning electrical components with POSITRON, de-energize and lock out the equipment, identify the contamination, list the materials involved, and run a compatibility test. Most problems come from what happens around the solvent rather than the solvent itself.

View POSITRON Product Details

POSITRON Product Summary: POSITRON is an ultra-high purity dielectric solvent. POSITRON is designed to remove oil, dirt, and carbon, and can be sprayed, wiped, or used in filtered and unfiltered parts washers.

Why Solvent Choice Matters for Electrical Cleaning

A solvent for electrical work needs to dissolve oil and carbon, leave little behind, and avoid creating new problems as it evaporates. POSITRON’s controlled evaporation rate is aimed at that last point: it is designed to help avoid moisture condensation problems, which can occur when a solvent evaporates quickly and cools the surface.

The same principles apply across electronics cleaning solvents, whether you need to clean electronic circuit boards or choose between electrical contact cleaning solutions.

What POSITRON Is Designed to Do

Many general-purpose solvents are not made with electrical work in mind, while POSITRON is designed for both electrical and mechanical cleaning. See below for more information from our technical documentation to help guide your decision.

Property Details
Soils removed Oil, dirt, and carbon
Key features Low odor, ultra-low residue, high dielectric strength, and a controlled evaporation rate
Application Spray, wipe, or filtered and unfiltered parts washers
Flash point 142°F

 

What to Check Before Cleaning Electrical Components

Before you start, we recommend working through the checks below:

  • Confirm the equipment is de-energized: Follow your lockout/tagout procedures, verify zero energy, and allow hot components to cool.
  • Identify the contamination: POSITRON is intended for oil, dirt, and carbon. Other residues may need a different product.
  • List the materials: Note plastics, seals, wire insulation, coatings, and markings. Suitability for electrical cleaning in general does not confirm compatibility with every material.
  • Run a compatibility test: Use your planned method, contact time, and drying. Check for swelling, softening, crazing, or smeared markings, again after full evaporation.

How to Apply POSITRON

Below is a recommended step-by-step for using POSITRON, though final usage will depend on the components and equipment being cleaned:

  1. Apply POSITRON by spraying, wiping, or dipping the parts to be cleaned. POSITRON works best when you use as little as possible, so start with a light spray.
  2. Allow about 5 to 10 minutes for POSITRON to work. It does not dry as quickly as some faster-evaporating solvents, so give it time to dissolve the soil.
  3. Follow with a second light spray of POSITRON as a rinse, which will push out the now soluble soils. Remember, the less you apply, the less you will have to remove.
  4. Remove the dissolved soil. POSITRON dissolves the soil, but it still needs to be removed mechanically. Wipe accessible surfaces with a clean rag. For hard-to-reach areas, such as motor windings, use compressed air, hot air, or a fan to blow out the soil. If you use compressed air, make sure it is free of particles and moisture.
  5. Confirm parts are dry and undamaged before re-energizing.

A Tip on Rags: When wiping parts that are wet with POSITRON, use a clean rag. We recommend avoiding lint-free rags, since they are often slightly oiled after laundering. That oil is barely noticeable, but it can leave a slight residue on the part.

If you use POSITRON in a parts washer, check that the washer and its seals are suited to a combustible liquid. Have other questions about how you are currently using POSITRON? Ask our Chemist.

Safety and Handling

Safety and Handling

  • Combustible liquid: With a flash point of 142°F, POSITRON falls under Category 4 of OSHA’s flammable liquids standard. Keep it away from heat, sparks, flames, and electrical arcing.
  • Aspiration hazard: May be fatal if swallowed and enters airways.
  • Skin irritation and sensitization: Causes skin irritation and may cause an allergic skin reaction. From our chemical PPE line-up, we can recommend the right glove type for use with POSITRON, should your business need it.
  • Drowsiness or dizziness: Use the ventilation specified in the Safety Data Sheet (SDS), especially in enclosed electrical rooms, and include POSITRON in your hazard communication program.

Compatibility Note: Product performance and material compatibility can vary based on the application, substrate, contamination, and operating conditions. Customers should evaluate and test the product for compatibility with their specific materials and operational needs before broader use.

Requesting Product Information for POSITRON

Requesting Product Information for POSITRON

At Ecolink, Inc., we help industrial customers evaluate solvents for electrical and mechanical cleaning. With 35+ years of industry experience, our team can help with your business’s cleaning needs. If you would like more information regarding POSITRON, please reach out to us today. POSITRON is available in the following sizes:

Packaging National Stock Number (NSN)
55-gallon drum 6850-01-412-0028
5-gallon pail 6850-01-412-0026
4 x 1-gallon case 6850-01-411-8815

 

Contact our team today; we look forward to assisting you!

Frequently Asked Questions

Can POSITRON replace chlorinated solvents?

POSITRON is labeled for use in place of chlorinated solvents in electrical and mechanical cleaning. Whether it suits your process depends on your soils, materials, and equipment, so test it before switching.

Can I request a sample of POSITRON before ordering?

Yes. Our team can arrange a free 1-pint sample so you can test POSITRON on your own components and equipment.

Important Notes

Educational Disclaimer: For educational purposes only. Always consult product SDS documentation and manufacturer recommendations before use.

General Informational Disclaimer: The information contained herein is provided in good faith, but shall not create any warranty, expressed or implied, by operation of law or otherwise, with any respect to any product. ECOLINK, INC. SPECIFICALLY DISCLAIMS ALL WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

Search here

Don’t forget to share this post!

Categories

Suggested Blog Posts

View all News
By Mark
How to Remove Heavy Grease and Oil from Metal Parts with VORTEX
Oct 09 2026

How to Remove Heavy Grease and Oil from Metal Parts with VORTEX

Heavy grease rarely comes off in one wipe, especially on gearboxes, housings, and parts pulled from storage. At Ecolink, we help companies find the right industrial...
By Mark
How to Loosen Seized Nuts, Bolts, and Fittings with PEN-T-10
Oct 05 2026

How to Loosen Seized Nuts, Bolts, and Fittings with PEN-T-10

A seized nut, rusted bolt, or frozen fitting can bring a maintenance job to a standstill. Here at Ecolink, we provide a wide array of aerosol options for our customers’...
By Mark
How Texas VOC Regulations Are Changing Aerosol Solvent Selection
Sep 21 2026

How Texas VOC Regulations Are Changing Aerosol Solvent Selection

Selecting an aerosol solvent in Texas isn't just a performance decision. For many Texas facilities, VOC regulations can also influence which aerosol cleaners,...
By Mark
Material Compatibility When Cleaning Electronic Assemblies: Choosing the Right Solvents
Sep 14 2026

Material Compatibility When Cleaning Electronic Assemblies: Choosing the Right Solvents

Choosing a solvent for electronic assembly cleaning isn't just about removing flux, oils, or other contaminants. The wrong cleaner can damage plastics, seals, labels,...
By Mark
Best Practices for Applying Industrial Aerosol Degreasers Safely
Sep 10 2026

Best Practices for Applying Industrial Aerosol Degreasers Safely

Chemical exposure remains one of the leading causes of workplace injuries, chronic illness, and fatalities across industrial environments. OSHA reports that cleaning...
By Mark
Why HFE Solvents Are Preferred for Precision Industrial Cleaning
Sep 08 2026

Why HFE Solvents Are Preferred for Precision Industrial Cleaning

Hydrofluoroether solvents are favored for precision cleaning due to their combination of cleaning performance and safety, one that traditional solvents struggle to...
By Mark
Latex Gloves and Chemical Resistance: What You Need to Know
Sep 07 2026

Latex Gloves and Chemical Resistance: What You Need to Know

Latex gloves and chemical resistance go hand in hand, but latex is not the right choice for every chemical. While latex gloves provide good resistance to many...
By Mark
How MIL-SPEC Cleaning Chemicals Support Aerospace Maintenance Standards
Sep 03 2026

How MIL-SPEC Cleaning Chemicals Support Aerospace Maintenance Standards

Aerospace maintenance depends on cleaning chemicals that perform predictably under extreme conditions without damaging sensitive materials, compromising safety, or...
By Mark
Signs It's Time to Switch to a Safer Industrial Degreaser
Sep 01 2026

Signs It’s Time to Switch to a Safer Industrial Degreaser

If your workers are reporting headaches after degreasing operations, your hazardous waste disposal costs keep climbing, or you've recently failed an environmental...
By Mark
Common Industries That Benefit from Aqueous Cleaners
Aug 19 2026

Common Industries That Benefit from Aqueous Cleaners

Industrial facilities across every sector face the same core challenge: removing oils, grease, machining fluids, and other contaminants from parts and surfaces without...
View all News